{"id":7411,"date":"2025-01-21T14:16:28","date_gmt":"2025-01-21T14:16:28","guid":{"rendered":"https:\/\/howtogeek.blog\/lv\/?p=7411"},"modified":"2025-01-21T14:16:28","modified_gmt":"2025-01-21T14:16:28","slug":"how-to-fix-error-reply-message-mismatch-595-0x253","status":"publish","type":"post","link":"https:\/\/howtogeek.blog\/lv\/how-to-fix-error-reply-message-mismatch-595-0x253\/","title":{"rendered":"K\u0101 nov\u0113rst k\u013c\u016bdas atbildes zi\u0146ojuma neatbilst\u012bbu 595 (0x253)"},"content":{"rendered":"<p>ERROR_REPLY_MESSAGE_MISMATCH ir izplat\u012bts \u0161\u0137\u0113rslis, ar ko saskaras izstr\u0101d\u0101t\u0101ji un sist\u0113mu administratori <strong>.<\/strong> \u0160\u012b probl\u0113ma var izrais\u012bt veiktsp\u0113jas v\u0101j\u0101s vietas un kav\u0113t sist\u0113mas efektivit\u0101ti. Ja esat sask\u0101ries ar \u0161o k\u013c\u016bdu, neuztraucieties\u00a0\u2014 \u0161\u012b rokasgr\u0101mata sniegs jums efekt\u012bvus risin\u0101jumus, k\u0101 taj\u0101 p\u0101rvietoties.<\/p>\n<h2 id=\"h-how-can-i-fix-error-reply-message-mismatch\">K\u0101 atrisin\u0101t probl\u0113mu ERROR_REPLY_MESSAGE_MISMATCH?<\/h2>\n<h3 id=\"h-1-debug-the-lpc-message-flow\">1.\u00a0Atk\u013c\u016bdojiet LPC zi\u0146ojumu pl\u016bsmu<\/h3>\n<ul>\n<li><strong>Atk\u013c\u016bdot\u0101ja pievieno\u0161ana:<\/strong> izmantojiet atk\u013c\u016bdot\u0101ju, piem\u0113ram <strong>, WinDbg,<\/strong> lai r\u016bp\u012bgi uzraudz\u012btu procesa sazi\u0146u.<\/li>\n<li><strong>R\u0101d\u012bt LPC darb\u012bbu:<\/strong> izpildiet komandu <code><strong>lpc -v<\/strong><\/code>, lai vizualiz\u0113tu akt\u012bvos LPC portus, zi\u0146ojumu rindas un gaido\u0161\u0101s darb\u012bbas.<\/li>\n<li><strong>Zi\u0146ojumu izseko\u0161ana:<\/strong> izp\u0113tiet zi\u0146ojumu p\u0113das, lai identific\u0113tu jebk\u0101das neatbilst\u012bbas klientu\u00a0ID un p\u0101rbaud\u012btu atk\u0101rto\u0161anas apstr\u0101d\u0101t\u0101ju esam\u012bbu.<\/li>\n<li><strong>P\u0101rraugiet pavedienu st\u0101vok\u013cus:<\/strong> p\u0101rliecinieties, vai klienta pavedieni pareizi gaida atbildes uz zi\u0146ojumiem \u2014 t\u0101di r\u012bki k\u0101 <strong>Process Explorer<\/strong> \u0161eit var b\u016bt \u013coti efekt\u012bvi.<\/li>\n<li><strong>Apstipriniet LPC zi\u0146ojuma integrit\u0101ti:<\/strong> p\u0101rbaudiet, vai gan LPC zi\u0146ojuma galvene, gan slodze atbilst pareizajiem form\u0101tiem.<\/li>\n<\/ul>\n<h3 id=\"h-2-increase-timeout-for-client-threads\">2. Piel\u0101gojiet klienta pavediena taimautu<\/h3>\n<ul>\n<li><strong>Atrodiet noildzes iestat\u012bjumus:<\/strong> taimautu bie\u017ei regul\u0113 j\u016bsu koda funkcija <strong>WaitForSingleObject .<\/strong><\/li>\n<li><strong>Palielin\u0101t taimauta ilgumu:<\/strong> mainiet taimauta ilgumu, lai nodro\u0161in\u0101tu uzticamas darb\u012bbas. Piem\u0113rs:<br \/>\n<code><strong>DWORD waitResult = WaitForSingleObject(hEvent, 5000); \/\/ Set to 5 seconds<\/strong><\/code><br \/>\n<img alt=\"dword waitresult 5000\" class=\"wp-image\" decoding=\"async\" height=\"48\" loading=\"lazy\" src=\"https:\/\/cdn.howtogeek.blog\/wp-content\/uploads\/2025\/01\/dword-waitresult-5000.webp\" title=\"dword waitresult 5000\" width=\"650\"\/>\n<\/li>\n<li><strong>Atk\u0101rtoti p\u0101rbaudiet lietojumprogrammu:<\/strong> p\u0113c korekcij\u0101m palaidiet lietojumprogrammu, lai p\u0101rbaud\u012btu, vai probl\u0113ma joproj\u0101m past\u0101v.<\/li>\n<li><strong>Bezgal\u012bgas gaid\u012b\u0161anas opcija:<\/strong> p\u0113c izv\u0113les, lai atk\u013c\u016bdotu, p\u0101rsl\u0113dzieties uz bezgal\u012bgu gaid\u012b\u0161anu:<br \/>\n<code><strong>DWORD waitResult = WaitForSingleObject(hEvent, INFINITE);<\/strong><\/code>\n<\/li>\n<\/ul>\n<h3 id=\"h-3-verify-synchronization\">3.\u00a0P\u0101rbaudiet sinhroniz\u0101ciju<\/h3>\n<ul>\n<li><strong>Piepras\u012bjuma un atbildes atbilst\u012bba:<\/strong> p\u0101rliecinieties, vai katrs klienta piepras\u012bjums tiek izpild\u012bts ar atbilsto\u0161o servera atbildi.<\/li>\n<li><strong>Ieviesiet Mutex kontroli:<\/strong> izmantojiet pareizu sinhroniz\u0101ciju, piem\u0113ram, mutexus vai semaforus, lai efekt\u012bvi apstr\u0101d\u0101tu piek\u013cuvi. Piem\u0113rs:<br \/>\n<code><strong>HANDLE hMutex = CreateMutex(NULL, FALSE, \"LPC_Sync_Mutex\"); WaitForSingleObject(hMutex, INFINITE); \/\/ Critical section ReleaseMutex(hMutex);<\/strong><\/code><br \/>\n<img alt=\"rokturis mutex\" class=\"wp-image\" decoding=\"async\" height=\"116\" loading=\"lazy\" src=\"https:\/\/cdn.howtogeek.blog\/wp-content\/uploads\/2025\/01\/handle-mutex-2.webp\" title=\"rokturis mutex\" width=\"635\"\/>\n<\/li>\n<li><strong>Izvairieties no sacens\u012bbu apst\u0101k\u013ciem:<\/strong> izvairieties no vienlaic\u012bgas piek\u013cuves piepras\u012bjumiem un atbild\u0113m, izmantojot vair\u0101kus pavedienus, lai mazin\u0101tu riskus.<\/li>\n<li><strong>P\u0101rbaudiet klienta\u00a0ID:<\/strong> p\u0101rbaudiet, vai klienta\u00a0ID LPC zi\u0146ojum\u0101 sakr\u012bt ar gaid\u012b\u0161anas pavedienu.<\/li>\n<\/ul>\n<h3 id=\"h-4-review-the-code\">4. P\u0101rskatiet un preciz\u0113jiet kodu<\/h3>\n<ul>\n<li><strong>Apstipriniet LPC piepras\u012bjumus:<\/strong> p\u0101rbaudiet, vai klienta \u0123ener\u0113tie LPC piepras\u012bjumi atbilst pie\u0146emamiem form\u0101tiem.<\/li>\n<li><strong>Gaida atbildi:<\/strong> p\u0101rliecinieties, vai klients pien\u0101c\u012bgi gaida servera atbildes, izmantojot <strong>ReplyWaitReceivePort<\/strong> vai <strong>WaitForSingleObject<\/strong> .<\/li>\n<li><strong>Ieviesiet atbildes kodu:<\/strong> izmantojiet:<br \/>\n<code><strong>NtReplyPort(ServerPortHandle, &amp;ReplyMessage);<\/strong><\/code>\n<\/li>\n<li><strong>P\u0101rbaudiet servera atbildes:<\/strong> p\u0101rliecinieties, vai serveris nes\u016bta dublik\u0101tus vai neder\u012bgas atbildes.<\/li>\n<li><strong>R\u012bkojieties ar atk\u0101rto\u0161anas k\u013c\u016bd\u0101m:<\/strong> efekt\u012bvi p\u0101rvaldiet atk\u0101rto\u0161anas k\u013c\u016bdas:<br \/>\n<code><strong>if (ReplyStatus! = STATUS_SUCCESS) { \/\/ Log error or retry }<\/strong><\/code><br \/>\n<img alt=\"statuss_success\" class=\"wp-image\" decoding=\"async\" height=\"97\" loading=\"lazy\" src=\"https:\/\/cdn.howtogeek.blog\/wp-content\/uploads\/2025\/01\/status_success.webp\" title=\"statuss_success\" width=\"463\"\/>\n<\/li>\n<li><strong>Visaptvero\u0161a re\u0123istr\u0113\u0161ana:<\/strong> nodro\u0161iniet r\u016bp\u012bgu \u017eurn\u0101lu p\u0101rvald\u012bbu gan piepras\u012bjumiem, gan atbild\u0113m, lai prec\u012bzi noteiktu neatbilst\u012bbas.<\/li>\n<\/ul>\n<h3 id=\"h-5-test-for-race-conditions\">5. Sacens\u012bbu apst\u0101k\u013cu tests<\/h3>\n<ul>\n<li><strong>Simul\u0113t slodzes test\u0113\u0161anu:<\/strong> izmantojiet stresa test\u0113\u0161anas r\u012bkus, lai model\u0113tu lielas slodzes scen\u0101rijus, atkl\u0101jot iesp\u0113jam\u0101s sinhroniz\u0101cijas k\u013c\u016bdas.<\/li>\n<li><strong>Atk\u013c\u016bdo\u0161anas p\u0101rtraukuma punktu pievieno\u0161ana:<\/strong> izmantojiet p\u0101rtraukuma punktus, lai uzraudz\u012btu pavedienu darb\u012bbu maksim\u0101l\u0101s lieto\u0161anas laik\u0101.<\/li>\n<li><strong>Ieviest aizkaves:<\/strong> apzin\u0101ti integr\u0113jiet aizkaves sav\u0101 kod\u0101:<br \/>\n<code><strong>Sleep(100);<\/strong><\/code>\n<\/li>\n<li><strong>Izmantojiet atk\u013c\u016bdo\u0161anas programmat\u016bru:<\/strong> t\u0101di r\u012bki k\u0101 <strong>Thread Analyzer<\/strong> vai <strong>Intel Inspector<\/strong> var pal\u012bdz\u0113t efekt\u012bvi noteikt sacens\u012bbu apst\u0101k\u013cus.<\/li>\n<\/ul>\n<p><strong>ERROR_REPLY_MESSAGE_MISMATCH<\/strong> atrisin\u0101\u0161ana var b\u016bt sare\u017e\u0123\u012bts process, un, ja joproj\u0101m saskaraties ar probl\u0113m\u0101m, izmantojiet t\u0101dus r\u012bkus k\u0101 <strong>Event Viewer<\/strong> , <strong>Process Monitor<\/strong> vai <strong>WinDbg<\/strong> padzi\u013cin\u0101tai anal\u012bzei.<\/p>\n<p>\u0160\u012b k\u013c\u016bda nav vien\u012bgais att\u012bst\u012bbas \u0161\u0137\u0113rslis. Noteikti skatiet m\u016bsu iepriek\u0161\u0113jos rakstus par <strong>ERROR_PORT_MESSAGE_TOO_LONG<\/strong> un <strong>ERROR_DBG_REPLY_LATER,<\/strong> lai uzzin\u0101tu vair\u0101k probl\u0113mu nov\u0113r\u0161anas taktiku, kas uzlabos j\u016bsu atk\u013c\u016bdo\u0161anas prasmes.<\/p>\n<h2>Bie\u017ei uzdotie jaut\u0101jumi<\/h2>\n<h3><strong>1.\u00a0Kas ir ERROR_REPLY_MESSAGE_MISMATCH k\u013c\u016bda?<\/strong><\/h3>\n<p>\u0160\u012b k\u013c\u016bda rodas, ja past\u0101v neatbilst\u012bba starp zi\u0146ojumiem, kas nos\u016bt\u012bti no klienta uz serveri, un gaid\u0101maj\u0101m atbild\u0113m. Parasti tas rodas sinhroniz\u0101cijas probl\u0113mu vai nepareizu zi\u0146ojumu form\u0101tu d\u0113\u013c.<\/p>\n<h3><strong>2.\u00a0K\u0101 es varu noteikt, vai man ir dar\u012b\u0161ana ar \u0161o k\u013c\u016bdu?<\/strong><\/h3>\n<p>\u0160o k\u013c\u016bdu var atpaz\u012bt, izmantojot atk\u013c\u016bdo\u0161anas r\u012bkus, piem\u0113ram, WinDbg, lai p\u0101rraudz\u012btu zi\u0146ojumus un p\u0101rbaud\u012btu atbil\u017eu statusu, sal\u012bdzinot ar nos\u016bt\u012btajiem piepras\u012bjumiem.<\/p>\n<h3><strong>3.\u00a0K\u0101di r\u012bki ir ieteicami \u0161\u012bs probl\u0113mas atk\u013c\u016bdo\u0161anai?<\/strong><\/h3>\n<p>Lai detaliz\u0113ti analiz\u0113tu un nov\u0113rstu k\u013c\u016bdu ERROR_REPLY_MESSAGE_MISMATCH, \u013coti ieteicams izmantot t\u0101dus r\u012bkus k\u0101 <strong>Event Viewer<\/strong> , <strong>Process Monitor<\/strong> un <strong>WinDbg .<\/strong><\/p>\n<p><a class=\"xiaomi\" href=\"https:\/\/windowsreport.com\/error-reply-message-mismatch\/\" rel=\"noopener noreferrer nofollow\" target=\"_blank\">Avots un att\u0113li<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ERROR_REPLY_MESSAGE_MISMATCH ir izplat\u012bts \u0161\u0137\u0113rslis, ar ko saskaras izstr\u0101d\u0101t\u0101ji un sist\u0113mu administratori . \u0160\u012b probl\u0113ma var izrais\u012bt veiktsp\u0113jas v\u0101j\u0101s vietas un kav\u0113t sist\u0113mas efektivit\u0101ti. Ja esat sask\u0101ries ar \u0161o k\u013c\u016bdu, neuztraucieties\u00a0\u2014 \u0161\u012b rokasgr\u0101mata sniegs jums efekt\u012bvus risin\u0101jumus, k\u0101 taj\u0101 p\u0101rvietoties. K\u0101 atrisin\u0101t probl\u0113mu ERROR_REPLY_MESSAGE_MISMATCH? 1.\u00a0Atk\u013c\u016bdojiet LPC zi\u0146ojumu pl\u016bsmu Atk\u013c\u016bdot\u0101ja pievieno\u0161ana: izmantojiet atk\u013c\u016bdot\u0101ju, piem\u0113ram , WinDbg, lai [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[9],"class_list":["post-7411","post","type-post","status-publish","format-standard","hentry","category-how-to","tag-windows"],"acf":[],"_links":{"self":[{"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/posts\/7411","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/comments?post=7411"}],"version-history":[{"count":1,"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/posts\/7411\/revisions"}],"predecessor-version":[{"id":7412,"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/posts\/7411\/revisions\/7412"}],"wp:attachment":[{"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/media?parent=7411"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/categories?post=7411"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/howtogeek.blog\/lv\/wp-json\/wp\/v2\/tags?post=7411"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}